<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-17 13-22-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
7.0 kHz 3.2 kHz 81 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19054 0,0052
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 2,48 dBr 3,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Freiburger Barockorchester "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0052 Acquired: 2024/12/17 13.21.54 Total samples: 19054 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,4 dBr MIN: 0,5 dBr AVE: 2,48 dBr % above 12,2 dBr: 0,0 Last value: 1,8 dBr (2024/12/17 13.21.54) 13.08 13.10 13.12 13.14 13.16 13.18 13.20 0 50 100 Dev. MAX [kHz] -1 0 1 2 3 4 Pm [dBr]